RNAutomation™ Discovery New

Catalog # M0028
Regulatory Status RUO
Description Abnova provides RNAutomation™ Discovery for Opentrons Flex customers with existing instruments to setup a new mRNA workstation. In addition to Opentrons distinct thermocycler, temperature, shaker-heater, magnetic block, and liquid handling modules, Abnova’s newly designed vacuum manifold module allows cellulose purification to remove dsRNA impurities from the mRNA product. The preprogrammed software provides liquid handling and robotic commands for mRNA in vitro transcription, capping, oligo dT and cellulose purification.

RNAutomation™ Discovery is supported by pre-validated mRNA bioreagents, kits, and plasticware consumables. It is amenable to additional software customization to accommodate specific requirements in mRNA preparation. RNAutomation™ Discovery enables scalable production and in process QC resulting in consistent mRNA analytics for downstream applications. Conventional manual synthesis and purification are challenged by inherent mRNA instability, susceptibility to degradation, impurity contamination, and variability in yield and quality.

RNAutomation™ Discovery provides the customers a seamless transition into the mRNA space. From efficacy and dose optimization studies to preclinical GLP and toxicology studies, RNAutomation™ Discovery is a powerful platform to address the needs of next generation mRNA vaccine development, biologic production, immunotherapy, and cell and gene therapies.

Opentrons™ Link: Opentrons Labworks Inc
Contact Info
  • +886-2-8751-1888
  • +886-2-6602-1218
Images

RNAutomation™ Discovery

RNAutomation™ Discovery

RNAutomation™ Discovery

RNAutomation™ Discovery

  • Overview

    RNAutomation_Exterior_Instrument_1.jpg (86 KB)

    RNAutomation_Component.png (412 KB)

     * FLEXTM.png (5 KB) 2025

     ** Abnova 2025 Patents Pending

    Regulatory Status: RUO

    Subtypes of RNAs

    • Self-Amplifying Messenger RNA (SAM)
    • Messenger RNA (mRNA)
    • Circular RNA (circRNA)

    RNA Processing

    • In Vitro Transcription (Co- vs Post-
      Transcriptional Modification)
    • Capping (Cap0 vs Cap1)
    • Oligo dT
    • Cellulose Purification

    Advantages

    Integrated Platform

    • Touch Screen Display*
    • 1-Channel 50ul Pipette Head*
    • 8-Channel 1000ul Pipette Head*
    • Two Prong Gripper*
    • Thermocycler*
    • Temperature Module*
    • Shaker-Heater*
    • Magnetic Block*
    • Vacuum Manifold**
    • Pre-Validated Bioreagents and Kits**
    • Pre-Programmed Softwares**

    Flexible Options

    • Scalable Production
    • In-Process QC
    • Software Customization

     

     
  • Specifications

     

    Hardware General Specifications

    Dimensions

    870mm(W) x 690mm(D) x 840mm(H), 34.25in(W) x 27in(D) x 33in(H)

    Weight

    88.5 kg / 195lb

    Power

    100–240 VAC, 50/60 Hz, 4.0 A/115 VAC, 2.0 A/ 230 VAC

    Operating Temperature

    20–25°C (Recommended)

    Operating Humidity

    40–60% RH (Recommended)

    Frame Composition

    Rigid steel and CNC aluminum, with removable polycarbonate panels

    Operation Environment

    Indoor use

    Operating Humidity (Environment)

    40% to 60% RH (Recommended)

    Status Display

    Real-time protocol status on LCD touchscreen

    Report Generation

    Through connected software / API

    Operating System

    Windows 10 or later, macOS 10.10 or later, Ubuntu 12.04 or later

    Interfaces/USB Ports

    USB 2.0, Ethernet, Wi-Fi (802.11 a/b/g/n/ac)

    Pipette Overview

    Air displacement pipetting (1–1000 µL), smart sensors for auto-calibration, error detection, supports 1-, 8-channel

    Pipette Volumes

    1–50 µL, 5–1000 µL (1-, 8-Channel)

    1-Channel Accuracy & Precision

    1 µL: ±8.00% / 0.08 µL; 10 µL: ±1.50% / 0.15 µL; 50 µL: ±1.25% / 0.625 µL; 5 µL: ±5.00% / 0.25 µL; 50/200/1000 µL: ±0.50%

    Gripper Specs

    Can manipulate plates, reservoirs, tip racks; move labware across deck or to trash chute

    Deck

    12 ANSI/SLAS deck slots, 4 staging slots; reconfigurable fixtures

    On-device Touchscreen

    7" LCD Gorilla® Glass 3, protocol control and status monitoring

    Connectivity

    802.11 a/b/g/n/ac dual-band Wi-Fi, USB 2.0, Ethernet

    Sterility

    Not a sterile environment; optional HEPA/UV accessory in development

    Viscosity

    Supports viscous liquid automation; refer to OT-2 best practices

     

    Vacuum Manifold Hardware Specifications

    Dimensions

    160.26mm(W) × 327.00mm(D)  × 106.00mm(H)

    Weight

    3.16 kg (CNC-machined aluminum)

    Plate Compatibility

    SBS-format 96-well filter and collection plates

    Channel Design

    One-to-one channel mapping with precision nozzle alignment

    Vacuum Source

    Internal solenoid switch + vacuum valve; external pump connection

    Vacuum Range

    Adjustable for high-throughput SPE without plate warping

    Materials

    CNC-machined aluminum, high-precision molded polymer components, stainless fasteners

    Seals

    Airtight annular plate design for stable vacuum retention

     

     

    Software Specifications

    Software Name

    RNAutomation™ Control Suite

    Base Platform

    Opentrons Flex App v8.1.0 or later (compatible with Protocol Designer v8.1.0)

    System Compatibility

    Fully compatible with Opentrons Flex robotic platform and its integrated modules (Thermocycler, Temperature Module, Heater–Shaker, Magnetic Block, and Vacuum Manifold)

    Automation Coverage

    Complete workflow automation for IVT, IVT Clean-Up, Capping, Capping Clean-Up, Oligo dT Purification, Oligo dT Clean-Up, Cellulose Purification, and Cellulose Clean-Up

    Standard Operation Format

    4X (4-well) configuration starting from IVT, yielding approximately 150 µg of purified mRNA

    Batch Operation Capability

    Optimized high-throughput 32X (32-well batch run); other configurations customizable upon request

    Interface

    Graphical user interface integrated in Flex App; supports protocol selection, progress monitoring, and run documentation

    Pre-Programmed Protocols

    Factory-validated liquid-handling sequences for Abnova mRNA reagent kits, with optimized aspiration/dispense speeds, mixing patterns, and module timing

    Customizability

    Optional customization under RUO license; parameters, reagent mapping, and workflow logic can be tailored to user requirements

    Data Handling

    Real-time logging of module status (temperature, shaking, magnetic, vacuum); exportable CSV/JSON run logs for QC traceability

    Integration

    Unified control of all Opentrons Flex modules via RNAutomation™ software layer

    Network / Update

    Offline operation supported; online updates available through Abnova-certified software packages

    Validation Environment

    Tested and validated under Opentrons Flex App v8.1.0 environment

    Regulatory Status

    Research Use Only (RUO)

    Language Support

    English (default); localization available upon request

  • Bioreagents
    • RNAutomation™ mRNA pTK4 EGFP Control (Catalog #: R0021)
    • RNAutomation™ mRNA pTK4 FLuc Control (Catalog #: R0022)
    • RNAutomation™ mRNA Co-Transcription Kit (Catalog #: KA7891)
    • RNAutomation™ 96-Well mRNA Oligo dT Kit (Catalog #: KA7892)
    • RNAutomation™ mRNA Co-Transcription Plasticware (Catalog #: PW7891)
    • RNAutomation™ 96-Well mRNA Oligo dT Plasticware (Catalog #: PW7892)
    • RNAutomation™ mRNA In Vitro Transcription (IVT) Kit (Catalog #: KA7330)
    • RNAutomation™ mRNA Capping Kit (Catalog #: KA7331)
    • RNAutomation™ mRNA Oligo dT Kit (Catalog #: KA7332)
    • RNAutomation™ mRNA Cellulose Kit (Catalog #: KA7333)
    • RNAutomation™ mRNA IVT Plasticware (Catalog #: PW7330)
    • RNAutomation™ mRNA Capping Plasticware (Catalog #: PW7331)
    • RNAutomation™ mRNA Oligo dT Plasticware (Catalog #: PW7332)
    • RNAutomation™ mRNA Cellulose Plasticware (Catalog #: PW7333)
    • RNAutomation™ dsRNA ELISA Kit (Catalog #: KA6886)
  • Applications
  • Flyers & Brochures
  • Support

    AbVideo™

    pdf_icon.gif (595 b) RNAutomation™ Discovery

     

     

    Troubleshooting

    pdf_icon.gif (595 b) RNAutomation™ RNase-Free Troubleshooting Guide

     

     

    Software Customization

    pdf_icon.gif (595 b) RNAutomation™ Software Customization

     

     

    Online Demo & Free Sample Testing

    pdf_icon.gif (595 b) RNAutomation™ Online Demo & Free Sample Testing
Contact Info
  • +886-2-8751-1888
  • +886-2-6602-1218